Old house wiring: what cloth-covered, ungrounded and two-prong actually mean for you

@garage_gabe · Sep 5, 2026 · 1.1k views
Difficultymedium

Cloth-covered NM from the 1940s and 50s is usually fine if the insulation is not crumbling; the problem is no ground. Options for two-prong outlets, in code order: run a ground wire to the panel or a grounded point; install a GFCI receptacle labelled "No Equipment Ground" (legal, protects people, does not protect surge protectors); or rewire. Never just swap in a three-prong without a ground; a tester will show "open ground" and surge strips will not work.

Knob and tube: not inherently dangerous if untouched, but it cannot be insulated over and most insurers want it gone.

#old-house#ungrounded#two-prong#knob-and-tube#electrical

20 💬 4 comments