Running a new circuit to a detached shed or garage: direct burial, conduit and a disconnect

@sparky_sal · Sep 8, 2026 · 360 views
Difficultyhard
Timea weekend
Cost$300 to $600

Feeder from the house panel: a 2-pole breaker (30A to 60A depending on the loads), 4-wire (two hots, neutral, ground: the neutral and ground are separated at the outbuilding subpanel), UF-B cable direct-buried 24" deep or THWN in PVC conduit at 18". The outbuilding gets its own grounding electrode (a rod or two) and a disconnect. Mark the trench with warning tape a foot above the cable.

Trenching is the hard part; rent a trencher for $100 and do it in an hour instead of a weekend with a shovel. Permit and inspection: yes.

#subpanel#shed#garage#direct-burial#conduit#electrical